Main product features:
|
|
Linear Mass and Dimensions |
|
Commercial Designation |
Height (mm) |
Rim Width (mm) |
Nominal Core Thickness (mm) |
Nominal Linear Mass (kg/m) |
|
Nominal |
Minimum |
Maximum |
Nominal |
Minimum |
Maximum |
|
3"x1ª core |
76,20 |
74,61 |
78,58 |
35,81 |
32,63 |
38,99 |
4,32 |
6,10 |
|
3"x2ª core |
38,05 |
34,87 |
41,23 |
6,55 |
7,44 |
|
4"x1ª core |
101,60
|
100,01
|
103,98
|
40,23 |
37,05 |
43,41 |
4,67 |
8,04 |
|
4"x2ª core |
41,80 |
38,62 |
44,98 |
6,27 |
9,30 |
|
4"x3ª core |
43,71 |
40,53 |
46,89 |
8,15 |
10,79 |
|
6"x1ª core |
152,40 |
150,81 |
154,78 |
48,77 |
45,59 |
51,95 |
5,08 |
12,20 |
|
6"x2ª core |
51,66 |
48,48 |
54,84 |
7,98 |
15,62 |
|
6"x3ª core |
54,79 |
51,61 |
57,97 |
11,10 |
19,34 |
| (*) sale upon consultation |
The U Profile mechanical properties are in conformity with the ABNT/NBR 7007/02, ASTM A36, and ASTM A572 norms. Dimensional features meet norm ASTM A6.
Main product features according to the ABNT/NBR 7007/02 norm:
|
|
Mechanical Properties - Steel Degree
|
|
MR 250 - NBR 7007
|
|
ASTM A-36 |
|
Minimum Outflow Limit (MPa) |
250
|
|
Minimum Resistance Limit (MPa) |
400
|
|
Maximum Resistance Limit (MPa) |
550
|
|
Minimum Lengthening (Lo = 200 mm)(%) |
20,0 (*)
|
|
(*) deductions are allowed in the minimum lengthening values according to product thickness. | |
|